Bentone Gas Burner BG450-2 Modulating

Bentone Gas Burner BG450-2 Modulating
  • Bentone Gas Burner BG450-2 Modulating
Get Best Quote
Approx. Price: Rs 2.23 Lakh / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
ModelBG450-2
Make/BrandBentone
Type of Industrial BurnersGas Industrial Burners
Usage/ApplicationIndustrial Gas
Avaliable Version120-550 kW
Number Of Stage2
Power Supply230 V
Frequency50 - 60 Hz

When biogas is used, Bentone shall always be contacted. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recommended for over- and under-pressure boilers. Design for easy maintenance. Energy saving.

 

Features:

Energy saving and compatible with environmental requirement

Quiet in operation and designed for easy maintenance

Reliable and trouble free

Designed and approved in accordance with the European standard EN 676

2-stage or modulating

Plug-in contact facilitates the installation

Two valves, slow opening

Gas connection left or right

Available for natural gas, LPG, town gas, bioga

When biogas is used, Bentone shall always be contacted

Request
Callback


Additional Information:

  • Port of Dispatch: undefined
  • Delivery Time: Ex stock
Yes! I am Interested
View PDF

Bentone Gas Burner BG450 Modulating

Bentone Gas Burner BG450 Modulating
  • Bentone Gas Burner BG450 Modulating
Get Best Quote
Approx. Price: Rs 1.8 Lakh / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
Make/BrandBentone
Usage/ApplicationIndustrial Gas
ModelBG450
Avaliable Version120-550 kW
Power Supply230 V
Frequancy50 - 60 Hz
Number of Stage2

When biogas is used, Bentone shall always be contacted. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recommended for over- and under-pressure boilers. Design for easy maintenance. Energy saving.

 

Features:

  • Energy saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Reliable and trouble free
  • Designed and approved in accordance with the European standard EN 676
  • 2-stage or modulating
  • Plug-in contact facilitates the installation
  • Two valves, slow opening
  • Gas connection left or right
  • Available for natural gas, LPG, town gas, biogas
  • When biogas is used, Bentone shall always be contacted
Request
Callback


Additional Information:

  • Port of Dispatch: undefined
  • Delivery Time: Ex Stock
Yes! I am Interested
View PDF

Bentone Gas Burner BG300

Bentone Gas Burner BG300
  • Bentone Gas Burner BG300
Get Best Quote
Approx. Price: Rs 99,000 / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
Model No.BG300
BrandBentone
ModelBG 300
ColorRed
Type of Industrial BurnersGas Industrial Burners
Make/BrandBentone
Packaging TypeCorrugated Box
Burner Output60-190
Usage/ApplicationIndustrial
Voltage230 V AC
Power60 - 190 kW
Number Of Stage1 & 2

Durva Enterprisr offering a better-quality range of Bentone Make Gas Burner and Spares that are manufactured using top quality raw materials which are sourced from certified vendors in the market. These are available in various sizes, models and as per the customer requirements. Clients can avail these from us at reasonable prices in the market.
 
We have following modal in stock:

Gas Burners:

STG 120/2,

 STG 146/2, 

 BG 200,

 BG 300,

 BG 400, 

BG 400-2,

BG 400 M,

BG 450, 

BG 550, 

BG 550 - 2,   etc model in stock.

 
Bntone burner spares:

We have Bentone Oil & Gas burner spres in stock.

 
Oil Burner spares:

Nozzles, QRB 1 photo cell, oil pump D 57C, 67C, 77C, blower motor, fan wheel, coupling, servo motor, fida ignition transformer, danfoss transformer, electrodes, cables, solenoid valve, etc.


Gas Burner Spares:

Dung multi block, electrodes, flame sensor, ignition transformer fida, danfoss, cofi,s ervo motor, blower motor, fan wheeL, etc.

Request
Callback


Additional Information:

  • Item Code: NA
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Ahmeabad
  • Delivery Time: Ex Stock
Yes! I am Interested
View PDF

Bentone Gas Burner BG400M Modulating

Bentone Gas Burner BG400M Modulating
  • Bentone Gas Burner BG400M Modulating
Get Best Quote
Approx. Price: Rs 1.82 Lakh / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
Make/BrandBentone
Usage/ApplicationIndustrial Gas
ModelBG400M
Voltage230 V
Stage2

When biogas is used, Bentone shall always be contacted. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recommended for over- and under-pressure boilers. Design for easy maintenance. Energy saving.

 

Features:

  • Energy saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Reliable and trouble free
  • Designed and approved in accordance with the European standard EN 676
  • Plug-in contact facilitates the installation
  • Two valves, slow opening
  • Gas connection left or right
  • Available for natural gas, LPG, town gas, biogas
  • When biogas is used, Bentone shall always be contacted

 

Flame monitoring and measurement of ionisation current:

  • The burner is monitored according to the ionisation principle. Check the ionisation current on start-up and on each service call. The reason for a low ionisation current may be leaking currents, bad connection to earth, dirt or a faulty position of the lame electrode in the burner head. Sometimes also a faulty gas/ air mixture may cause too weak a ionisation current. The ionisation current is measured by means of a microampere meter (μA) connected in series with the flame electrode and the gas burner control. Connect the μA-meter, see igure. Min. required ionisation current according to to the table. In practice this current must be considerably higher, preferably more than 10 μA. All the gas burners are equipped with a ionisation cable that can be slit which facilitates the connection of the μA-device.

 

Adjustment of max. gas pressure switch:

  • The burner is equipped with a max. gas pressure switch only on request. It should stop the burner if the gas pressure exceeds the set value. The burner can then only be re-started manually (gas burner control or overpressure switch). Remove the protective cover. Connect a pressure gauge for measuring the rated gas pressure. Decide on the pressure at which the gas pressure switch should switch off. Turn the adjustment knob to this value. Tolerance on the scale ±15%.


Adjustment of air pressure switch

  • The air pressure switch should stop the burner if the air volume is reduced. The air proving device shall be adjusted in such a way that if there is insuficient air supply at the highest or lowest burner operating stage, the device operates before the supervised pressure is less than 80% of the pressure at the controlled stage and the CO content of the combustion products exceeds 1% by volume


Adjustment of min. gas pressure switch:

  • The min. pressure switch should react if the gas pressure is too low and prevent the burner from starting. Too low a gas pressure during operation should stop the burner. The burner may start again when the rated gas pressure has been reached. Remove the protective cover. Connect a pressure gauge for measuring the rated pressure. Decide on pressure at which the gas switch should switch off. Set this pressure by means of the valve. Carefully turn the knob until the gas pressure switch switches off. The value shown on the scale should then approximately correspond with the value shown on the pressure gauge. Tolerance on scale appr. ± 15 %. Open the ball valve


General rules:

  • Care should be taken by the installer to ensure that no electrical cables or fuel/gas pipes are trapped or damaged during installation or service/maintenance.
Request
Callback


Additional Information:

  • Port of Dispatch: undefined
  • Delivery Time: Ex Stock
Yes! I am Interested
View PDF

Bentone Gas Burner STG 146

Bentone Gas Burner STG 146
  • Bentone Gas Burner STG 146
Get Best Quote
Approx. Price: Rs 61,000 / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
BrandBentone
Make/BrandBentone
Voltage220 - 240 V
Frequency50 Hz
Rated inlet pressures20 mbar

STG 146 Gas Burner a compact burner, easy to install. Ducted or conventional air inlet. Designed for easy maintenance. Industry standard components are used. A soft pulsation free start. Wide adjustment range and high efficiency with constant combustion values. When Biogas is used, Bentone shall always be contacted. Also available in biogas versions. Biogas will affect the output and the components of the burner.

 

Features:

  • Energy saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Reliable and trouble free
  • Designed and approved in accordance with the European standard EN 676
  • Compact design
  • Plug-in contact facilitates the installation
  • Ducted or conventional air inlet
  • Available for natural gas, LPG, town gas, biogas
  • Two valves, slow opening
  • When biogas is used, Bentone shall always be contacted

Mounting On The Boiler:

  • Fit the enclosed flange and gasket to the boiler. If new fixing holes must be drilled, use the mixing large as a pattern. Use mixing screws M8-M10. Push the burner into the large and ix it by means of the screws in the large. Ensure that the burner is it absolutely straight. The gas armature is from the factory mounted in a horizontal position. The connection of the incoming gas line
  • is made from the right side. Should it for some reason be necessary to make the gas connection in any other direction the armature can be turned 180° to the left and upwards. It is also
  • possible to connect the gas to the multi-bloc straight backward. The armature can also be extended so that it comes outside the boiler if there is not enough room. Ensure that the distance between the inner assembly and the gas armature is not too long. If the distance is too long there will not be time for the burner to light.


Installation example:

    Connect the gas to the burner by means of the ball valve. To facilitate service a union nut is used between the gas supply system and the ball valve. Ensure that the union nut, ball valve, and tubing make it easy to remove the burner for inspection and service.

    Measures And Checks Before Start-Up:
    • General rules: Care should be taken by the installer to ensure that no electrical cables or fuel/gas pipes are trapped or damaged during installation or service/maintenance.
    • Inner assembly: Ensure that the ignition and ionization electrodes are correctly adjusted. The sketch shows the correct measurements.
    • Gas quality: Ensure that the burner head is meant for the gas quality to be used.
    • Venting: The gas line is vented by loosening the screw on the test nipple for the inlet Pressure. Connect a plastic hose and conduct the gas into the open. After having vented the gas line tighten the screw again.
    • Leakage control: When making a leakage control of the gas supply system the solenoid valve should be closed. If any leakage, locate the source by means of soapy water or a leak location spray. After tightening repeat the test
    • Electric function test: Ensure that phase and neutral are not reversed. The gas shut-off cock should be closed. To prevent the gas pressure switch from locking out it should be linked temporarily. After the main switch has been switched on and the thermostats have been adjusted the pre-purging period begins (30-50 sec.). At the end of this period, the pre-ignition period starts (0,5-3 sec. dependent on the design of the gas control). The gas valve is energized and opens. At the end of the safety time (2-3 sec.) the gas control locks out.
      Request
      Callback


      Additional Information:

      • Pay Mode Terms: T/T (Bank Transfer)
      • Port of Dispatch: undefined
      • Delivery Time: Ex Stock
      Yes! I am Interested
      View PDF

      Bentone Gas Burner BG 300M Modulating

      Bentone Gas Burner BG 300M Modulating
      • Bentone Gas Burner BG 300M Modulating
      Ask For Price
      Product Price :Get Latest Price

      Product Details:

      ModelBG 300M
      Usage/ApplicationIndustrial
      BrandBentone
      Avaliable Version60-190 kW
      Number Of Stage1 & 2

      Slow opening solenoid valve. Gas connection left or right. Recommended for over- and under-pressure boilers. Design for easy maintenance. Energy saving. When biogas is used, Bentone shall always be contacted.

       

      Features:

      • Energy saving and compatible with environmental requirements
      • Quiet in operation and designed for easy maintenance
      • Reliable and trouble free
      • Designed and approved in accordance with the European standard EN 676
      • Plug-in contact facilitates the installation
      • Two valves, slow opening
      • Hinged flange
      • Gas connection left or right
      • Available for natural gas, LPG, town gas, biogas
      • When biogas gas is used, Bentone shall always be contacted


      Adjustment of burner:

      • The burner is from the factory pre-set to an average value that must then be adjusted to the boiler in question. All burner adjustments must be made in accordance with boiler manu-facturers instructions. These must include the checking of lue gas temperatures, average water temperature and CO2 or O2 concentration.


      General instructions:

      • The installation of the gas burner must be carried out in accordance with current regulations and standards. The installers of gas burners should therefore be acquainted with all regulations and ensure that the installation complies with the requirements. The installation, mounting and adjustment should be made with the greatest care and only the correct gas should be used.Operating instructions. The operating instructions accompanying the burner should be left in a prominent position in the boiler room.


      Instructions:

      • The user should be thoroughly instructed in the function of the gas burner and the whole installation. The supplier must instruct the user.


      Inspection and maintenance

      • Daily inspection is advisable.


      Startup:

      • After the burner has been itted to the boiler and the electric connection, the leakage control, the venting and the electric function test have been carried out, the burner will be ready for start-up. Howerer, study the sections dealing with adjustments of multi-bloc, com bustion air and combustion head. Open the ball valve and switch on the main switch. If the burner starts the actual adjustment can be made.


      Adjustment of burner head:

      • The burner is equipped with an adjustment device changing the po si tion of the brake plate in the burner head. This is used to adjust the cor rect pressure drop over the combustion device in order to obtain a good pulsation free combustion. Which position to use depends on input and overpressure in the boiler. A general rule is that the lower capacity the smaller the opening between brake plate and combustion device.


      Commissioning of installation

      • Control of the combustion. The combustion quality is checked by means of a lue gas analysis device. Adjust the burner to appr. 20% excess air in accordance with the table. Check the lue gas temperature. Calculate the eficiency. Check also the actual gas volume on the gas meter so that the correct input is achieved.


      Service:

      • Service should only be carried out by qualiied personnel. Replacement parts should be of the same make and approved by the same authorities as the original. If the burner is converted to ire another gas quality it must be re-commissioned.
        Request
        Callback


        Additional Information:

        • Port of Dispatch: undefined
        • Delivery Time: Ex Stock
        Yes! I am Interested
        View PDF

        Bentone Gas Burner BG400 Modulating

        Bentone Gas Burner BG400 Modulating
        • Bentone Gas Burner BG400 Modulating
        Ask For Price
        Product Price :Get Latest Price

        Product Details:

        Minimum Order Quantity1 Unit
        ModelBG400
        Make/BrandBentone
        Usage/ApplicationIndustrial
        Number Of Stage1 & 2
        Available Version60.0 - 318.0 kW

        Hinged flange. Slow opening solenoid valve. Gas connection left or right. Recommended for over- and under-pressure boilers. Design for easy maintenance. Energy saving. When Biogas is used, Bentone shall always be contacted

         

        Features:

        • Energy saving and compatible with environmental requirements
        • Quiet in operation and designed for easy maintenance
        • Reliable and trouble free
        • Designed and approved in accordance with the European standard EN 676
        • Plug-in contact facilitates the installation
        • Two valves, slow opening
        • Hinged flange
        • Gas connection left or right
        • Available for natural gas, LPG, town gas, biogas
        • When biogas gas is used, Bentone shall always be contacted

         

        General instructions

        • The installation of the gas burner must be carried out in accordance with current regulations and standards. The installers of gas burners should, therefore, be acquainted with all regulations and ensure that the installation complies with the requirements. The installation, mounting, and adjustment should be made with the greatest care and only the correct gas should be used.


        User manual:

        • The installation and maintenance instructions supplied with the burner must be kept at an easily accessible location in the boiler room.


        Instructions:

        • The user should be thoroughly instructed in the function of the gas burner and the whole installation. The supplier must instruct the user.


        Inspection and maintenance:

        • Inspection as needed, preferably daily. Maintenance per service schedule.


        Startup:

        • After the burner has been fitted to the boiler and the electric connection, the leakage control, the venting, and the electric function test have been carried out, the burner will be ready for start-up. However, study the sections dealing with adjustments of multi-bloc, combustion air, and combustion head. Open the ball valve and switch on the main switch. If the burner starts the actual adjustment can be made.


        Adjustment of burner head:

        • The burner is equipped with an adjustment device changing the position of the brake plate in the burner head. This is used to adjust the cor rect pressure drop over the com bus tion device in order to obtain a good pulsation free combustion. Which position to use depends on input and overpressure in the boiler. A general rule is that the lower capacity the smaller the opening between the brake plate and combustion device.


        Commissioning of installation:

        • Control of the combustion. The combustion quality is checked by means of a flue gas analysis device. Adjust the burner to appr. 20% excess air in accordance with the table. Check the flue gas temperature. Calculate the efficiency. Check also the actual gas volume on the gas meter so that the correct input is achieved.

         

        Service:

        • Service should only be carried out by qualiied personnel. Replacement parts should be of the same make and approved by the same authorities as the original. If the burner is converted to ire another gas quality it must be re-commissioned. If town gas is to be ired the combustion head must be converted and the gas train adjusted to suit (e.g.a larger gas armature or a different spring in the governor may be required).

         

        Gas Burner:

        • Conditions favourable to disruption-free operation of the system can only be guaranteed through the interaction between three factors – electricity, gas low and combustion air. A change in any of these factors may cause disruptions. It has been shown that a large proportion of disruptions can be attributed to relatively small things.
        Request
        Callback


        Additional Information:

        • Port of Dispatch: undefined
        • Delivery Time: Ex stock
        Yes! I am Interested
        View PDF

        Bentone Gas Burner BG300-2 Modulating

        Bentone Gas Burner BG300-2 Modulating
        • Bentone Gas Burner BG300-2 Modulating
        Ask For Price
        Product Price :Get Latest Price

        Product Details:

        Minimum Order Quantity1 Unit
        ModelBG300-2
        Make/BrandBentone
        Usage/ApplicationIndustrial
        Voltage230 V
        Number Of Stage1 & 2

        Gas connection left or right. Recommended for over- and under-pressure boilers. Design for easy maintenance. Energy saving. When biogas is used, Bentone shall always be contacted. Slow opening solenoid valve.

        Features:
        • Energy saving and compatible with environmental requirements
        • Quiet in operation and designed for easy maintenance
        • Reliable and trouble free
        • Designed and approved in accordance with the European standard EN 676
        • Plug-in contact facilitates the installation
        • Two valves, slow opening
        • Hinged flange
        • Gas connection left or right
        • Available for natural gas, LPG, town gas, biogas
        • When biogas gas is used, Bentone shall always be contacted
        Request
        Callback


        Additional Information:

        • Port of Dispatch: undefined
        • Delivery Time: Ex stock
        Yes! I am Interested
        View PDF

        Bentone Gas Burner BG550 Modulation

        Bentone Gas Burner BG550 Modulation
        • Bentone Gas Burner BG550 Modulation
        Ask For Price
        Product Price :Get Latest Price

        Product Details:

        Minimum Order Quantity1 Unit
        Power Supply230 V
        ModelBG550
        Make/BrandBentone
        Usage/ApplicationIndustrial Gas
        Available Version140-628 kW

        When changing from one type of gas to another only a few components need replacing. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recommended for over- and underpressure boilers. Designed for easy maintenance. Energy saving. Also available in biogas versions. Biogas will affect the output and the components of the burner. Available with LMV burner management system or standard burner control systems.

        Features:
        • User-friendly display control
        • Electronic ratio-control between air and fuel
        • Build-in leakage control (VPS)
        • Communication to the main control unit (superior system) via Modbus
        Request
        Callback


        Additional Information:

        • Port of Dispatch: undefined
        • Delivery Time: Ex Stock
        Yes! I am Interested
        View PDF
        X

        Explore more products



        Reach Us
        Kalapi Bhatt (Owner)
        Shop No. D/6, Chandralay Flats, Near Naran Pura Cross Road
        Ahmedabad- 380013, Gujarat, India



        Call Us

        Share Us

        F GT L


        Send E-mailSend SMS